Skip to content

Radiation Therapy Errors and Overdoses in New York

A radiation treatment error can deliver too much radiation, leave part of the tumor undertreated, or expose healthy tissue that the plan was meant to protect.

External beam radiation therapy uses a machine outside the body to direct radiation at a target. Other types of cancer treatment include brachytherapy, which places a radiation source in or near the tumor, and systemic treatments that carry radioactive material through the body.

This article focuses on external beam treatment because its planning, positioning, and session records show how a delivery error can arise.

Should Your Cancer Have Been Found Sooner?

Contact us today for a free consultation.

How External Beam Radiation Is Planned

The radiation planning process usually starts with a CT scan called a simulation. The scan is taken in the position you will use during treatment. The team marks the areas that need radiation and nearby organs it wants to protect.

The radiation oncologist prescribes the dose and number of sessions, called fractions. The team uses that prescription to build a plan showing how the dose should be distributed.

The prescription and plan answer different questions. The prescription states the intended dose and schedule. The plan shows how the beams are expected to deliver that dose to the target while limiting exposure to nearby tissue. A plan can match the total dose in the prescription and still have a problem if it targets the wrong area.

The Checks That Help Catch Radiation Errors

The American Association of Physicists in Medicine's 2021 guideline on radiation plan and chart review describes checks before and during an external beam treatment course.

  1. Before the first session. A medical physicist reviews whether the planned dose per session and total dose agree with the prescription. The review also checks that the plan uses the correct scan and matches the documented treatment setup.

  2. At treatment. Radiation therapists confirm the approved instructions and position the patient. When image guidance is used, images taken at the machine help the team check alignment against the plan. A time-out gives the team a chance to verify key details before delivery.

  3. During and after the course. For a conventional multi-session course, the guideline recommends reviewing the chart within each block of five fractions to check whether treatment is proceeding as intended. An end-of-treatment review checks the completed record. When a change affects the planned dose, the guideline calls for a new plan review.

New York also regulates radiation safety. The state's July 22, 2026 adoption notice for 10 NYCRR Part 16 identifies changes to Section 16.24 covering quality assurance and verification of radiation therapy treatments.

The regulation in effect when care was delivered matters when reviewing an earlier course. Professional guidance helps explain how checks work in practice, and the applicable regulation supplies the facility's legal requirements.

How a Plan or Delivery Error Can Happen

A 2018 study of radiation oncology incident reports reviewed 396 high-priority reports selected from a voluntary reporting system. It identified problems such as approval of a flawed plan, incorrect instructions about how far to move the patient or treatment table, and incorrect movement despite the right instructions.

These selected reports describe ways errors can happen. They do not show how frequently patients experience them.

Possible error

What a review would compare

Incorrect dose or an extra session

The signed prescription, any authorized revisions, and the number and dose of fractions recorded as delivered.

Wrong target or inadequate tumor coverage

The simulation images and approved plan to see which areas were marked for treatment and how much radiation the plan assigned to them.

Incorrect positioning

The treatment-day images, setup instructions, and recorded position adjustments to see whether the planned target and actual setup matched.

A problem after the plan changed

The dated plan versions, approvals, and delivery history to see which version was active for each session.

An error can affect cancer control as well as healthy tissue. In a 2010 analysis from an advanced head and neck cancer trial, patients who received at least 60 gray, a unit of radiation dose, had lower two-year overall survival when their plans had major deficiencies than when their plans complied from the start.

This was a comparison within one trial. It cannot determine how a planning problem affected an individual patient's outcome.

What Records Help Verify a Radiation Error?

Ask the facility's radiation oncology department or medical records office how to request the parts of your treatment chart that cover the course in question.

New York Public Health Law 18 on access to patient information generally gives qualified requesters an opportunity to inspect covered information within ten days of a written request and to obtain copies within a reasonable time, subject to statutory limits.

  • Prescription and approved plans. These establish the intended dose, target, number of sessions, and authorized changes.

  • Simulation images, treatment-day images, and delivery records. These help show how you were positioned and what the system recorded for each session.

  • Treatment summaries and follow-up records. These can document changes in the schedule, symptoms, later imaging, and care for a suspected injury.

Write down dates and symptoms as you remember them. Our guide to documenting your cancer care explains how a timeline can help you keep track of appointments and changes. Access to the patient chart is subject to different rules from access to internal incident reviews or peer-review files.

New York Filing Deadlines for Radiation Treatment Errors

Under New York CPLR 214-a, a malpractice action generally must start within two years and six months of the alleged error or the last treatment in a qualifying course of continuous treatment for the same condition.

Visits you request solely to check the status of the condition are excluded from the statute's definition. The statute also has a discovery rule for an alleged negligent failure to diagnose cancer. A claim about radiation delivered incorrectly generally follows the ordinary treatment-error rule.

Type of claim

What the deadline generally requires

Municipal provider, where applicable

Serve a notice of claim within 90 days of the applicable starting date under General Municipal Law 50-e. For wrongful death, the notice period generally starts when the estate representative is appointed. Where General Municipal Law 50-i applies, there is also a separate lawsuit deadline, ordinarily one year and 90 days after the event for personal injury or two years after death for wrongful death.

Negligence claim against New York State

Under Court of Claims Act 10, a personal injury claim generally must be filed and served within 90 days of accrual. Timely service of a notice of intention on the Attorney General generally allows two years from accrual to file and serve the claim. Wrongful death against the State has separate timing and service requirements.

Federal provider covered by the Federal Tort Claims Act

28 U.S.C. 2401(b) generally requires presenting a written claim to the proper federal agency within two years after accrual and filing suit within six months after the agency mails a final denial.

For a qualifying wrongful death case, New York Estates, Powers and Trusts Law 5-4.1 generally gives the estate's personal representative two years from the death to sue. EPTL 5-4.3 addresses recoverable financial losses resulting from the death and certain medical, nursing, and funeral expenses.

The applicable notice and filing rules depend on who operated the facility, the type of claim, and the dates in the record. If the patient was a child, CPLR 208 may extend some deadlines, but its infancy toll generally cannot extend a malpractice claim beyond ten years from accrual.

Request a Review of a Possible Radiation Treatment Error

Contact your treatment team about symptoms or urgent questions concerning your radiation care. If you were told that a treatment error occurred or you found a discrepancy in your records, Porter Law Group offers a free consultation to discuss the treatment timeline and which deadlines may apply.

You can start with the treating facility, approximate dates, and what you were told. Call 833-888-LATE or request a case review.

Attorney Advertising. This article provides general educational information. For medical or legal advice about your circumstances, consult a qualified healthcare provider or attorney. Reading this article or contacting the firm does not create an attorney-client relationship.

Frequently Asked Questions

Does one extra radiation session prove malpractice?

One extra session can point to a discrepancy that needs review. The prescribed schedule may have changed, so the signed prescription and amendments should be compared with the delivery record. If an unauthorized session occurred, the review still needs to determine what tissue received the extra dose and what injury, if any, resulted.

Is there a percentage above the prescription that proves a radiation injury?

A percentage difference alone cannot establish injury. A reviewer needs to know where the additional radiation went, the dose per session, and how much the affected organ had already received. The same percentage can have different implications depending on the dose and which tissues were exposed. A threshold used in a study does not decide an individual claim.

Can a blood test show that my radiation treatment was delivered incorrectly?

There is no routine blood test that can determine whether an external beam radiation session matched the approved plan. Blood tests may help your care team evaluate symptoms or changes during treatment. The delivery question usually requires comparing the prescription, treatment plan, and machine or chart records for the sessions in question.

Could an error occur even if the total recorded dose is correct?

Yes. The total recorded dose can agree with the prescription while radiation reaches a different location than intended. This is why a reviewer may need both the treatment-day images and positioning records. Those materials help show whether the target was aligned as planned and whether nearby tissue received an unexpected dose.

Do I need a doctor's opinion before contacting a lawyer?

You can contact a lawyer with the records and dates you have. Under New York CPLR 3012-a, the attorney ordinarily certifies that they reviewed the facts and consulted a qualified clinician before concluding there is a reasonable basis to bring the case. The statute provides alternatives in specified circumstances, including when a deadline prevents timely consultation.

Free case evaluation

Talk With a New York Cancer Lawyer

If a delayed diagnosis changed your family's future, Porter Law Group can review what happened and explain your options.